TR3271 EVENT MANAGEMENT
90: ZTR3-EVT-PROC-ABEND
Probable Cause
The necessary system resources could not be allocated to the
TR3271 I/O process or a COUP parameter is incorrect or inconsis-
tent. The I/O process stops and cannot be used. The TR3271
process deletes itself.
The value of
nnnnn
indicates the reason for the abend. The error
codes in the 1 through 999 range indicate a memory-related error,
while error codes in the 1000 through 1999 range indicate a COUP
configuration error.
The memory related errors (1-999) are as follows:
Error Code Meaning
1 ALLOCATESEGMENT failed
2 USESEGMENT failed
3 LOCKMEMORY failed
4 DEFINEPOOL failed
5 GETLOCALPOOL failed
6 GETLOCALPOOL from translation
table failed
7 Remaining memory less than
MAXLOCALAREA
8 GETLOCALPOOL for #ZSPI failed
9 ALLOCATE XSEG for #ZSPI failed
10 DEFINEPOOL for #ZSPI failed
The configuration related errors (1000-1999) are as follows:
Error Code Meaning
1000 Check microcode (FETOOCHEAP)
1001 Invalid number of units
1002 CSMLDEV error
1003 Bad device type
1004 LHLDEV is different from WRPDT
1005 NDD is zero
1006 Cannot communicate with CSM
1007 CLIP subchannel address out of
range
1008 CLIP has been configured