TR3271 Management Programming Manual

TR3271 EVENT MANAGEMENT
164: ZTR3-EVT-CSS-LINE-ERR
Value Meaning
14 Modem error or loss
15 BCC error
16 Not used
17 Not used
18 Invalid response for protocol
19 No buffer space in device
20 Improper buffer format
21 Read buffer too small
22 Reset request received
23 EOT received
24 Unknown device status
25 Line overran CLIP
26 Not used
27 Operation timeout
28 Line not configured
29 Invalid parameter
30 SU not ready
31 RVI received with status
The value of
param3
indicates the CLIP subdevice number.
Recommended Action
Note the values of all the parameters in the message text, and
contact your Tandem representative.
7-57