TR3271 Management Programming Manual

ERROR NUMBERS AND ERROR LISTS
5: ZTR3-ERR-NOT-PTP-SU
5: ZTR3-ERR-NOT-PTP-SU
The CONNECT command has been issued, but the TR3271 subdevice
from which you want to make the connection is not defined as a
PTP subdevice. It must be defined as a PTP subdevice.
ZSPI-TKN-ERRLIST type ZSPI-TYP-LIST
ZSPI-TKN-ERROR type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME type ZSPI-TYP-STRING
ZCOM-TKN-OBJTYPE type ZSPI-TYP-ENUM
ZSPI-TKN-ENDLIST type ZSPI-TYP-SSCTL
Tokens
ZSPI-TKN-ERROR is the standard SPI error token described in the
Distributed Systems Management (DSM) Programming Manual
. Its
value consists of the target subsystem ID and the error number
ZTR3-ERR-NOT-PTP-SU. This token is always present in the error
list.
ZCOM-TKN-OBJNAME is the object name on which the error occurred
in the command. This token is present in the error list if its
presence is relevant to the cause of the error. That is, if the
error was detected after the subsystem made choices based on the
object name, this token is present in the error list. Otherwise,
it is omitted from the list.
ZCOM-TKN-OBJTYPE is the object type provided with the command on
which the error occurred. Its value defines the type of object
against which the command was issued; it is always the object
type SU.
Recommended Action
Alter the subdevice to a PTP SU using the ALTER command or
determine which subdevices have already been defined as PTP
subdevices using the INFO command. Reissue the CONNECT command
using the PTP subdevice you just defined or use one of those
previously defined that is not currently connected to a TR3271
subdevice.
A-7