COMMANDS AND RESPONSES
ABORT Command
ZCOM-ERR-TKN-VAL-INV (-30)
Your management application specified the SU object and the
the SUB modifier with a value ZCOM-VAL-SUB-ONLY. The SU
object accepts only the value ZCOM-VAL-SUB-NONE or ZCOM-VAL-
SUB-ALL for the SUB modifier.
ZSPI-TKN-ENDLIST indicates the end of a data list or an error
list. See "SPI Standard Definitions" in Section 5 for details.
ZSPI-TKN-CONTEXT specifies whether there are more reply messages
to be received for a response. If this token is present, the
response continues to the next reply message. If this token is
not present, the reply message is the last to be received. See
"SPI Standard Definitions" in Section 5 for details.
Operational Notes
ABORT is a sensitive command.
When the command is completed, the line and subdevices are
placed in the STOPPED summary state.
The line must be in the STARTED summary state when this
command is issued.
If you abort a pass-through protocol (PTP) SU, the SU is
disconnected from the AM3270 subdevice on the other end.
For more controlled termination of lines and subdevices, use
the STOP command.
To initiate the operation of lines and subdevices, use the
START command.
Use the STATUS command to determine the summary states of the
objects.