TS/MP 2.5 System Management Manual

1162
*1162* RESIZESEGMENT ERROR (errnum)
Cause. A error occurred during a call to the Guardian RESIZESEGEMENT or
CHECKRESIZESEGMENT procedure.
Effect. The command fails.
Recovery. For additional information, see the descriptions of the RESIZESEGEMENT or
CHECKRESIZESEGMENT procedures in the Guardian Procedure Calls Reference Manual.
1163
*1163* LICENSING ERROR: PATHWAY PRODUCTS MUST BE LICENSED
Cause. PATHMON could not start up because it could not confirm that either the NonStop TS/MP
product or the Pathway /TS product is licensed for your site.
Effect. System startup fails.
Recovery. Either the NonStop TS/MP product or the Pathway/iTS product must be licensed before
the PATHMON process can start an application. If you have secured a license for the NonStop
TS/MP or Pathway/iTS product, perform the following steps:
1. Confirm that one or both licensing files–ZLICA58 (NonStop TS/MP) or ZLICSA59 (Pathway/iTS)
are located in the $SYSTEM.ZPATHWAY subvolume.
2. Confirm that the files located in $SYSTEM.ZPATHWAY are secured NxNx, where x is any
valid Guardian security setting.
If a licensing file is present and properly secured, applications running under the licensed product
must start up and run as expected.
1164
*1164* LICENSING ERROR: (product-name) PRODUCT NOT LICENSED
Cause. You have issued a command for a NonStop product that is not licensed for your site. For
example, you have tried to use PATHCOM to define a server class, but NonStop TS/MP is not
licensed for your site.
Effect. The command fails.
Recovery. The product named in the error message, either NonStop TS/MP or Pathway/iTS, must
be licensed before you can add objects controlled by that product. If you have secured a license
for the product named in the message, perform the following steps:
1. Confirm that the appropriate licensing file—ZLICSA58 (NonStop TS/MP) or ZLICSA59
(Pathway/iTS)—is located in the $SYSTEM.ZPATHWAY subvolume.
2. Confirm that all files located in $SYSTEM.ZPATHWAY are secured NxNx, where x is any
valid Guardian security setting.
If the appropriate licensing file is present and properly secured, you can define objects controlled
by the licensed product.
1165
*1165* MAXIMUM NUMBER OF LINK MANAGERS EXCEEDED
244 PATHMON Messages (Numbers 1000-1499)