TS/MP 2.5 System Management Manual

1003: ZACL-EVT-BACKUP-ABENDED
The backup domain coordinator process terminated unexpectedly. ]
Unconditional Tokens
ZACL-TKN-EVENT-LEVEL token-type ZACL-TYP-EVENT-LEVEL.
ZACL-TKN-EVENT-CPU-NUMBER token-type ZSPI-TYP-INT.
ZACL-TKN-EVENT-CPU-NUMBER token-type ZSPI-TYP-INT.
Conditional Tokens
ZACL-TKN-EVENT-TERM-STOPPER token-type ZSPI-TYP-PHANDLE.
ZACL-TKN-EVENT-TERM-SSID token-type ZSPI-TYP-SSID.
ZACL-TKN-EVENT-TERM-TEXT token-type ZSPI-TYP-STRING.
Event-Message Text
1003 - Backup process in CPU cpu-number terminated
abnormally, comp-code error-code, [ stopper stopper-id, ] [
term-ssid term-ssid, ] term-info term-info, [ term-text termtext
Token Descriptions
ZACL-TKN-EVENT-LEVEL
has the value of ZACL-VAL-EVENT-LEVEL-WARNING.
ZACL-TKN-EVENT-CPU-NUMBER
contains the number of the CPU on the local system in which the backup domain coordinator process
was terminated. This token is the subject of the event message.
ZACL-TKN-EVENT-ERROR-CODE
contains the completion code associated with the backup process termination. A completion code
of -4 indicates that only the backup process, not both members of the process pair, terminated.
ZACL-TKN-EVENT-ERROR-DETAIL
contains the termination information code returned from the process-termination operation. If the
value of this token is 0 (zero), the token is null and can be regarded as omitted from the message.
If the backup process was stopped externally (indicated by completion code 6), the value of this
token is the creator user identifier of the external process that stopped the backup process.
ZACL-TKN-EVENT-TERM-STOPPER
contains the process handle of the process that initiated the termination. This token is included only
if the process was stopped externally.
ZACL-TKN-EVENT-TERM-SSID
contains the SPI subsystem identifier associated with the process-termination operation. This token
is omitted if no subsystem identifier was associated with the termination.
ZACL-TKN-EVENT-TERM-TEXT
contains the termination text associated with the process-termination operation. This token is omitted
if no termination text was associated with the termination.
Effect. The primary domain coordinator process creates a new backup process.
Recovery. If the problem persists, contact your HP support analyst.
EMS Message Range 1000 through 1009 279