TS/MP Management Programming Manual (H06.05+, J06.03+)

ACS Subsystem Messages
HP NonStop TS/MP Management Programming Manual540082-005
14-22
EMS Messages 1010 through 1019
Recovery. Correct the requester program.
1019: ZACL-EVT-INCOMP-RQST-VER
Token Descriptions
ZACL-TKN-EVENT-LEVEL
has the value of ZACL-VAL-EVENT-LEVEL-WARNING.
ZACL-TKN-EVENT-PROCESS-ID
contains the process handle of the requester process that sent the incompatible
request message. This token is the subject of the event message.
If the process identified by this token still exists when the event message text is
generated, the EMS event message formatting facilities convert process handle
tokens to named or unnamed process descriptor strings. If the process no longer
exists, EMS generates a question mark instead of the process descriptor string.
Cause. An ACS subsystem process received an incompatible version of a request
message.
Effect. The request message is ignored. A reply containing an FEINVALOP (2) error is
returned to the requester process.
Recovery. This event indicates that incompatible versions of ACS components are
installed on different systems in the same domain.
Unconditional Tokens
ZACL-TKN-EVENT-LEVEL token-type ZACL-TYP-EVENT-LEVEL.
ZACL-TKN-EVENT-PROCESS-ID token-type ZSPI-TYP-PHANDLE.
Event-Message Text
1019 - Incompatible request version received from process
process-id