TS/MP Management Programming Manual (H06.05+, J06.03+)

ACS Subsystem Messages
HP NonStop TS/MP Management Programming Manual540082-005
14-23
EMS Messages 1020 through 1029
EMS Messages 1020 through 1029
1020: ZACL-EVT-INVALID-RPLY-MSG
An ACS subsystem process received an invalid reply message or a reply message that
has an incompatible version.
Token Descriptions
ZACL-TKN-EVENT-LEVEL
has one of the values ZACL-VAL-EVENT-LEVEL-ERROR or ZACL-VAL-EVENT-
LEVEL-FATAL.
ZACL-TKN-EVENT-PROCESS-ID
contains the process handle of the server process that sent the invalid reply
message. This token is the subject of the event message.
If the process identified by this token still exists when the event message text is
generated, the EMS event message formatting facilities convert process handle
tokens to named or unnamed process descriptor strings. If the process no longer
exists, EMS generates a question mark instead of the process descriptor string.
Effect. The reply message is discarded. The operation associated with the request is
aborted.
Recovery. Contact your HP support analyst.
Unconditional Tokens
ZACL-TKN-EVENT-LEVEL token-type ZACL-TYP-EVENT-LEVEL.
ZACL-TKN-EVENT-PROCESS-ID token-type ZSPI-TYP-PHANDLE.
Event-Message Text
1020 - Invalid reply message received from process process-id