TS/MP System Management Manual (H06.05+, J06.03+)
PATHMON Messages (Numbers 1000-1499)
HP NonStop TS/MP System Management Manual—541819-007
13-23
PATHMON Messages
Recovery. If the primary processor failed, reload the processor so that the PATHMON
process can create a backup process. If a PRIMARY or SWITCH command was run,
this is an informational message only; no corrective action is needed.
1078
Cause. A PATHMON process internal-consistency check failed. This is an internal
error.
Effect. The PATHMON process terminates.
If the DUMP attribute is enabled, the PATHMON process creates a dump file before
terminating.
Recovery. Contact your HP representative and provide all relevant information as
follows:
•
Descriptions of the problem and accompanying symptoms
•
Details from the message(s) generated
•
Your PATHMON configuration file and the PATHMON process version
•
A description of the application task that was in progress when the error was
encountered
•
Supporting documentation such as Event Management Service (EMS) logs, trace
files, and dump files, if applicable
If your local operating procedures require contacting the Global Customer Support
Center (GCSC), supply your system number and the numbers and versions of all
related products as well.
1079
Cause. A START SERVER command failed because the SET SERVER NUMSTATIC
attribute is set to 0.
Effect. The PATHMON process cannot start a server process until it receives a
request from a the LINKMON process or a TCP.
Recovery. Define the SET SERVER NUMSTATIC attribute with a value from 1
through 4094.
*1078* PATHMON, FATAL ERROR ( %P-register )
*1079* NO STATIC SERVERS DEFINED