ViewPoint Manual

Server Assigns and Parameters
ViewPoint Manual426801-001
A-5
Server Parameters
Table A-2. Server Parameters (page 1 of 5)
ALTERNATE-DISTRIBUTOR-CPU (-1)
provides the CPU number in which ViewPoint runs the alternate events distributor. If the
CPU field of the Alternate Event Configuration screen is left blank and this parameter is
defined with a valid CPU, ViewPoint uses the value of the parameter; otherwise, ViewPoint
uses the CPU of the server.
Servers: ZVPT-EVNT-COLL
AUTO-SUSPEND (FALSE)
allows event collection to be suspended if an outstanding critical or action event is about to
be scrolled out of the event cache. The operator is notified that an unacknowledged critical
or action event is about to be scrolled out of the event cache. The event collection resumes
once the operator acknowledges the event. To turn on the option, set this parameter to
TRUE.
Servers: ZVPT-EVNT-COLL
BELLRESET (-1)
provides the volume setting (0-7) to which to restore the bell if the bell volume is changed on
a write to the twenty-fifth line. By default (-1), the bell volume is not reset. If a number
higher than 7 is specified, the number 7 is used, and if a number lower than -1 is specified,
-1 is used.
Servers: ZVPT-EVNT-COLL
BELLVOLUME (-1)
provides the volume setting (0-7) of the bell for the 6530 terminal. The bell is used when the
ZVPT-EVNT-NTFY server writes to the twenty-fifth line. The default value (-1) indicates
the terminal-configured setting is used. If a number higher than 7 is specified, the number 7
is used, and if a number lower than -1 is specified, -1 is used. If 0 is used, the bell is not rung.
Servers: ZVPT-EVNT-COLL
CALL-EXTRAS-DELETE (FALSE)
indicates whether the program unit ZVPT-EXTRAS-DELETE is called whenever a manual
delete is attempted on the Primary-Events screen. TRUE indicates the program unit is called;
FALSE (the default setting) indicates that the program is not called.
Servers: ZVPT-EVNT-COLL
CLEANUP-HOUR (23)
identifies the hour on a 24-hour clock at which the garbage collection cleanup tasks are
scheduled to run. The default value is 23 (11 p.m.). Possible values are 0 through 24. The
value 24 is interpreted as 0.
Servers: ZVPT-GARB-COLL