Error
0222
Cause. A Measure error was returned by the MEASREADACTIVE call for the
specified object.
Effect. An ILLEGALMEASNUM error results in an automatic restart of the
measurement.
Recovery. See the Measure Reference Manual for an explanation of Measure errors.
0223
Cause. A file-system error was reported while ViewPoint was opening or reading the
status configuration file. The error reported is shown as the second number in the
message.
Effect. Certain status items may be missing from your screen.
Recovery. See the System Procedure Errors and Messages Manual for an explanation
of file-system errors.
0224
Cause. An incorrect file code was specified for the status configuration file.
Effect. Certain status items may be missing from your screen.
Recovery. Enter a correct code. The file code for status configuration files should
be 450.
0225
Cause. A file-system error occurred on the current configuration file. The error number
is specified as the second number in the message.
Effect. Certain status items may be missing from your screen.
Recovery. See the System Procedure Errors and Messages Manual for an explanation
of file-system errors.
MEASURE error returned while sampling the object:
File error reported while reading status configuration.
The status configuration file has an incorrect file code.
File error occurred while updating the configuration file: