ViewPoint Manual

Error Messages
ViewPoint Manual426801-001
B-19
Error
0243
Cause. A request to the status display server resulted in an internal error.
Effect. Certain status items may not be measured.
Recovery. Supply the error numbers when reporting this internal error to a Compaq
representative.
0244
Cause. A file-system error occurred while ViewPoint was accessing the status cache
file. The status-display server refers to a file that by default is STATCACH on the
default subvolume. This can be changed by the status-cache assign. The file-system
error number is provided with this message.
Effect. Certain status items may not be measured.
Recovery. See the System Procedure Errors and Messages Manual for an explanation
of file-system errors.
0245
Cause. A status item record was deleted before the percentage busy value could be
computed.
Effect. The status item is not measured.
Recovery. Check to see if the screen update interval is longer than the value specified
for the SAMPLE-AGE-MAX-MINUTES server parameter.
0246
Cause. The Measure subsystem is running, but a file-system error was returned from
the MEASOPEN call in starting the measurement. This probably indicates that an error
occurred during access to the MEASDATA file on the default subvolume. The file-
system error number is included in the message.
Effect. Certain status items may not be measured.
Recovery. See the System Procedure Errors and Messages Manual for an explanation
of Measure and file-system errors.
Status display server request error:
File error occurred while accessing the status cache file:
Sample cannot be computed; interval is less than
sample-age-max.
File error returned while starting the measurement: