ViewPoint Manual

Error Messages
ViewPoint Manual426801-001
B-20
Error
0247
Cause. The Measure subsystem is running, but a NEWPROCESS file-system error was
returned from the MEASOPEN call in starting the measurement. This probably
indicates an error during the start of the Measure file-handling program (MEASFH on
SYSnn subvolume). The file-system error number is included in the message.
Effect. Certain status items may not be measured.
Recovery. See the System Procedure Errors and Messages Manual for an explanation
of Measure and file-system errors.
0248
Cause. The Measure subsystem is running, but the MEASOPEN call returned a
NEWPROCESS error when starting the measurement. This probably indicates an error
when starting the Measure file handling program (MEASFH on SYSnn subvolume).
The high-order portion of the NEWPROCESS error is included in the message.
Effect. Certain status items may not be measured.
Recovery. See the System Procedure Errors and Messages Manual for an explanation
of Measure and file-system errors.
0249
Cause. The Measure sample required that PUP be started. The NEWPROCESS call
returned an error. This is commonly due to a security error on the PUP program file
(PUP on SYSnn subvolume). The file-system error number is included in the message.
Effect. Certain status items may not be measured.
Recovery. See the System Procedure Errors and Messages Manual for an explanation
of Measure, NEWPROCESS, and file-system errors.
0250
Cause. The measurement required PUP be started, but an error was returned from
NEWPROCESS while starting PUP. The high-order portion of the NEWPROCESS
error is included in the message.
Effect. Certain status items may not be measured.
File error returned from NEWPROCESS while starting the
measurement:
NEWPROCESS error occurred while starting the measurement:
File error returned from NEWPROCESS while starting the PUP:
NEWPROCESS error occurred while starting the PUP: