Error
0324 (A)P
Cause. You tried to display old events when they were not available.
Effect. No events are displayed.
Recovery. Specify more recent events on the event configuration screen.
0325
Cause. This file-system error occurred during an OPEN of the last event cache file.
Effect. The Last Events screen might not be updated correctly.
Recovery. See the System Procedure Errors and Messages Manual for an explanation
of file-system errors.
0326
Cause. The event collection server has been configured not to manage events for the
current display. Either the server’s Pathway configuration is in error, or the requester is
sending its request to the wrong collection server.
Effect. Events are not displayed.
Recovery. Verify that any “ignore” options are set correctly. See Appendix A, “Server
Assigns and Params,” in this manual for details.
0328
Cause. The version of this event configuration file is no longer recognized. You cannot
use it.
Effect. The current configuration file cannot be used.
Recovery. Try creating a new configuration file.
0329
Cause. A SEND to the event configuration server resulted in an error.
No old events were found; continuing with current events.
Error occurred when opening the last event cache file:
This display is not managed by this event collection server.
The event configuration file version is unrecognized.
ZVPT-EVNT-CNFG send error: