Virtual Hometerm Subsystem (VHS) Manual (H06.03+)

Command Descriptions
Virtual Hometerm Subsystem (VHS) Manual429311-001
7-30
INFO Command
Max. primary log files is the maximum number of primary log files that can be
created before there is a rollover and the first primary log file created is purged.
Prompt file is the name of the file which contains all prompts received by the VHS
process. The prompt file must always be present. If there is no prompt file specified
when the VHS process is started, a default prompt file is assigned by the VHS
process.
Next save file is the name of the next saveabend file to be created (when a
process traps into Inspect, VHS creates this saveabend file).
Accept-ext-ascii-character allows the VHS process to accept or not accept non-
ASCII characters. If the Accept-ext-ascii-character is set to ON, VHS accepts non-
ASCII characters. If Accept-ext-ascii-character is set to OFF, VHS does not accept
non-ASCII characters. By default VHS sets Accept-ext-ascii-character to OFF.
Add-text-to-event is the parameter that specifies if the token text is to be added to
all EMS events. If the Add-text-to-event is set to ON, VHS will add the token text to
all EMS event messages. If Add-text-to-event is set to OFF, VHS will not add the
token text to all EMS messages. By default VHS sets Add-text-to-event to ON.
Automatic-inspect-processing specifies if VHS is to process Inspect prompts or
let the user manage them via the VHS Prompt Browser screen. When Automatic-
inspect-processing is ON, VHS automatically handles Inspect prompts. When
Automatic-inspect-processing is OFF, VHS does not process Inspect prompts; they
will be managed via the VHS Prompt Browser screen. By default VHS sets
Automatic-inspect-processing to ON.
Backup-creation-message-delay is the delay in minutes between each
occurrence of the backup creation failure message. The delay must be between 0
and 999. If there is no delay specified, the default delay is 5 minutes.
Environment-name is the name of the VHS process environment. The string
value assigned to Environment-name must be between quotes ( " ). The first
character must be alphabetic. All other characters can be alphabetic or numeric or
a “-”. The environment name length can be from 1 to 8 characters long.
File-code is used for the primary log file creation. The numeric value assigned to
File-code must be between 0 and 65535. If there is no numeric value assigned
then the default value is 0.
Generate-display-event specifies if an EMS event message is to be generated for
a display type message. When Generate-display-event is set to ON, VHS
generates EMS events for display type messages. When Generate-display-event
is set to OFF, VHS does not generate EMS events for display type messages. By
default VHS sets Generate-display-event to ON.
Generate-inspect-event specifies if an EMS event message must be generated
for Inspect type messages. When Generate-inspect-event is set to ON VHS
generates EMS events for Inspect type messages. When Generate-inspect-event
is set to OFF VHS does not generate EMS events for Inspect type messages. By
default VHS sets Generate-inspect-event to ON.