Virtual Hometerm Subsystem (VHS) Manual (H06.03+)
VHS Event Messages
Virtual Hometerm Subsystem (VHS) Manual—429311-001
C-79
128: ZVHS-EVT-INSP-TABLE-FULL-SEC
Unconditional Tokens
ZSPI-TKN-SSID is the subsystem ID for VHS and is described in the SPI Programming
Manual. The value of this token is always ZVHS-VAL-SSID.
ZEMS-TKN-EVENTNUMBER is the event message number. The value for this event
message is ZVHS-EVT-INSP-TABLE-FULL-SEC (128).
ZEMS-TKN-SUBJECT-MARK is the standard EMS token that immediately precedes
the subject token ZVHS-TKN-PNAME.
ZEMS-TKN-EMPHASIS is set to ZSPI-VAL-TRUE because this event message is
critical.
(ZEMS-TKN-) CPU, CRTPID, GENTIME, LOGTIME, PIN, SYSTEM, USERID and
TEXT are described under EMS Standard Definitions on page C-5.
ZEMS-TKN-SUPPRESS-DISPLAY is set to ZSPI-VAL-FALSE.
ZVHS-TKN-ENVIRONMENT-NAME is the name of the environment of this VHS. If no
environment name is defined using the VHS startup parameter ENVIRONMENT-
PARAM, then the default value is VHS.
ZVHS-TKN-PNAME is the process name of VHS.
ZVHS-TKN-INSPECT-OBJECT is the name of the last loaded section.
ZVHS-TKN-INSPECT-FILE is the name of the VHS Inspect file.
ZVHS-TKN-VHS-OBJECTFILE is the object file name of VHS.
ZVHS-TKN-VERSION is the version of VHS.
Probable Cause
The VHS Inspect file contains too many sections. The limit is 100 sections.
Recommended Action
Edit the file and remove unnecessary sections. The number of sections must not
exceed 100. VHS will automatically reload the Inspect file when another application
traps into Inspect. See Section 3, Using VHS for more detail on the format of the
Inspect file.
Event-Message Text
timestamp pid environment-name: Too many sections in VHS
inspect table. Limit of 100 sections reached. Inspect file
inspect-file. Stopped at line number number1.number2.