Virtual Hometerm Subsystem (VHS) Manual (H06.03+)
VHSCI Messages
Virtual Hometerm Subsystem (VHS) Manual—429311-001
G-28
Interprocess Communication Messages
-00028
Probable Cause. Token length is either too long or too short.
Recommended Action. Contact your service provider.
-00029
Probable Cause. A command was issued with a missing required token.
Recommended Action. Contact your service provider.
-00030
Probable Cause. An illegal value was encountered in a supported token.
Recommended Action. Recovery action depends on the token in error and on the
value specified in that token. For information about recovery from this error, see the
subsystem-specific reference manual.
-00031
Probable Cause. A required attribute value was omitted.
Recommended Action. Supply the required value and reissue the request.
-00032
Probable Cause. A command request was issued in which the command version was
a higher level than the version of the target subsystem, and the command contained
tokens unknown to the subsystem. This error can also occur if the version of a field in a
structured token is at a higher level than the version of the target subsystem.
Recommended Action. Communication with the subsystem is not possible. Refer to
the SPI Programming Manual for information about recovery from version
incompatibility. The experienced user could do a VERSION command and determine
Internal Error: Invalid Token Length: Token Code: HEX-num
(tnm:num, Len: num)
Internal Error: Required token Missing: Token Code: HEX-num
(tnm:num)
Internal Error: Invalid Value: text (tnm:num, Offset: num)
for obj-name
Required Value Missing for Attribute: text (tnm:num, Offset:
num)
Incompatible Version: num, Command required subsystem to be
num for obj-name