X25AM Programming Manual

Procedures Summary for X25AM
X25AM Programming Manual527201-001
A-12
SETPARAM 4
Set the Clear Cause and Diagnostic codes:
SETPARAM 4
Get the Reset Cause and Diagnostic codes:
Set the Reset Cause and Diagnostic codes:
SETPARAM 5
Get the Restart Cause and Diagnostic codes:
SETPARAM 6
Read the page-mode terminal error counters.
CALL SETPARAM (filenum, function, Clear Cause code
byte, Diagnostic code byte, length is 2 bytes)
filenum = file number
function = 2
Clear Cause code byte
= some value
Diagnostic code byte = some value
length is 2 bytes = 2
CALL SETPARAM (filenum, function,,, Reset Cause
code byte, Diagnostic code byte,
length is 2 bytes)
CALL SETPARAM (filenum, function,Reset Cause code byte,
Diagnostic code byte, length is 2 bytes)
filenum = file number
function = 4
Reset Cause code byte
= 0
Diagnostic code byte = some value
length is 2 bytes = 2
CALL SETPARAM (filenum, function, Restart Cause code
byte, Diagnostic code byte, length is 2 bytes)
filenum = file number
function = 5
Restart Cause code byte
= 0
Diagnostic code byte = some value
length is 2 bytes = 2 bytes
CALL SETPARAM (filenum, function,,, 8 integer
values, length is 16 bytes)