X25AM Programming Manual

Procedures Summary for X25AM
X25AM Programming Manual527201-001
A-13
SETPARAM 7
Initialize the counters.
Table A-4 lists the error counters for SETPARAM 6.
SETPARAM 7
Get the configured Closed User Group (CUG) ID.
Set the configured Closed User Group (CUG) ID.
CALL SETPARAM (filenum, function, 8 integer values,
length is 16 bytes)
filenum = file number
function = 6
8 integer values
= Refer to Ta ble A -4
length is 16
bytes
= 16
Table A-4. Page-Mode Error Counters (SETPARAM 6)
Number Counter Function
1 Response Timeouts # of times ITI failed to obtain a reply from the terminal
before Page Mode Timer expired.
2 LRC Errors # of block checksum errors ITI found in data coming from
the terminal.
3 Bad Text Errors # of out-of-sequence text blocks.
# of text blocks with invalid framing.
# of text blocks received when no READ is pending.
4 Illegal Reply Errors # of unsolicited replies,
# of invalid responses,
# of terminal reset sequence.
5Unused
6Unused
7Unused
8Unused
CALL SETPARAM (filenum, function,,, cug^id,
length)
CALL SETPARAM (filenum, function, cug^id, length)
filenum = file number