X25AM Programming Manual

Diagnostic Codes for X25AM
X25AM Programming Manual527201-001
B-3
Reset Diagnostics
27/39 Data packet too long (data greater than packet size).
Reset packet too long (greater than 5).
Interrupt packet too long (greater than 4).
Interrupt Confirmation packet too long (greater than 3).
29/41 Restart or Restart Confirmation packet with LCN less than or
greater than 0 while in state D1, D2 (DCE), or D3 (DTE).
2B/43 Unauthorized interrupt confirmation (interrupt confirmation, but no
unacknowledged interrupt has been transmitted).
2C/44 Unauthorized interrupt (second interrupt, but first interrupt has not
been acknowledged).
30/48 Reset timeout (T22/T12).
33/51 T22/T11 timeout occurred waiting for reset indication.
53/83 Inconsistent Q-bit setting.
82/130 CPU or CLB switch, LCN in state P4.
83/131 Data or interrupt received on an out-of-order PVC, LCN is restored
to operational status. 85/133 NAM pseudo call.
86/134 NAM pseudo clear.
C0/192 State table error.