BackBox H4.00 User Manual
Product Description
28 BackBox H4.00 User Manual
For operations initiated through the Web interface the Guardian login
information (Domain Manager node and user-id) entered to access the
Web interface is used.
Authorization specification
Each of the three authorizations, Read, Write and Control, specifies how the user
accessing the volume should compare to the volume owner. The accessing user can
be:
N Any node, any user-id
C Any node, same group number
U Any node, same user-id
A Same node, any user-id
G Same node, same group number
O Same node, same user-id
? Use authorizations that were set at backup time
. Disabled access
‘?’ is a special value that cannot be entered, but is displayed by the BackPak GUI for
volumes that were created in a RESTRICTED Data Store.
For such volumes, the domain does not hold the RW authorizations; the access
control is done by the VTC against the authorization specifications that were set at
backup time and copied as metadata in the Data Store.
‘.’ is another special value that cannot be entered or removed. This is the value
displayed for WRITE access when a volume is in a RESTRICTED or SECONDARY Data
Store. Such volumes can never be written for a new backup.
bbox-secure specification
“bbox-secure=rwc” can be added to the MOUNTMSG DEFINE attribute. The keyword
and authorizations are not case sensitive.
Example of specification through a TAPE DEFINE:
RESET DEFINE *
DELETE DEFINE =TAPE1
SET DEFINE CLASS TAPECATALOG
SET DEFINE FILEID FULL-BACKUP
SET DEFINE POOL BBOX_BACKUP
SET DEFINE LABELS BACKUP
SET DEFINE MOUNTMSG "Full backup bbox-secure=GGO"