BackBox H4.00 User Manual

Operations
71 BackBox H4.00 User Manual
value 1: replace '_' characters by space
value 2: replace '+' characters by space.
Default value is 0.
[START_TIME HH:MN]
Specific to StoreOnce. See after the Sample regular report.
Minimum start time in the day. If the macro is run before, nothing will be
executed.
From 00:00 to 23:59. Default value is 00:00.
START_TIME and END_TIME must be both specified or both omitted.
[END_TIME HH:MN]
Specific to StoreOnce. See after the Sample regular report.
The macro will not execute anything if run after this time. If the job is still
processing at this time, the VTC will complete the current volume and stop
processing.
From 00:00 to 23:59. Default value is 23:59.
START_TIME and END_TIME must be both specified or both omitted.
[MAX_DURATION HH:MN]
Specific to StoreOnce. See after the Sample regular report.
Elapsed time after which the VTC will complete the current volume and stop
processing.
From 00:00 to 99:59. Default value is no limitation.
Sample regular report:
When a Data Store is not configured for StoreOnce, the macro waits for the result
and displays a control report showing the deleted volumes.
LSD3-BB023 Delete backed up Windows files 2007-08-21 10:38:36
Store id to clean up: ALL
Data Store: WIN1
Label Last update Last accsss Size (MB)
----- ---------------- ---------------- -----------
Path: \\208.180.1.87\LSAL_on_D\LSD3\WIN1
LMW104 2007-07-30 16:45:07 2007-07-30 16:44:59 31
Path: \\BB1\LS_E\LSD3\WIN1
LMW103 2007-08-21 10:32:49 2007-07-30 16:31:33 31
LMW111 2007-08-21 10:37:16 2007-08-21 10:37:03 31
Path: \\happy\lsal\lsd3\win1
LMW106 2007-08-01 14:03:56 2007-07-30 17:08:15 31
LMW107 2007-08-07 18:20:48 2007-08-07 18:20:39 31
LMW112 2007-08-21 10:33:51 2007-08-21 10:33:40 31