Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)
Termination Info: 0
CLIMSCMP Messages
Error messages:
• Error: Only SUPER group users are allowed to run 'CLIMSCMP'.
• Error: No value specified for the 'run-option' run-option.
• Error: Unsupported run-option 'run-option' specified.
• Error: 'clim-name' is not a configured CLIM.
• Error: 'clim-name-1' and 'clim-name-2' are not configured CLIMs.
• Error: SSH connection could not be established to the CLIM 'clim-name'.
• Error: SSH connection could not be established to the CLIMs 'clim-name-1' and
'clim-name-2'.
• Error: No CLIMs specified for the comparison of enclosures.
• Error: Only two CLIMs can be specified for the comparison of enclosures.
• Error: 'clim-name' is not a storage CLIM.
• Error: 'clim-name-1' and 'clim-name-2' are not storage CLIMs.
• Error: Could not successfully execute 'lunmgr -e' on the CLIM 'clim-name'.
• Error: Could not successfully execute 'lunmgr -e' on the CLIMs 'clim-name-1' and
'clim-name-2'
Warning messages:
• Warning: Only SUPER group users are allowed to run 'CLIMSCMP'.
• Warning: Following enclosures are single ported.
Tip: Finding an Available UDP Port (IP CIP Only)
Use the LISTOPENS MON command to display UDP ports in use. See the Expand Configuration
and Management Manual for examples of finding available UDP ports.
CLIM and Host Incompatibility
If the CLIM stays in the STARTING state, the CLIM software might be incompatible with the host.
In this case, event 5228 is generated. To fix this, upgrade or downgrade the CLIM software to
match the host RVU version. See Chapter 4 (page 133) for the CLIM upgrade procedure. See the
Software Installation and Upgrade Guide for your host system RVU for procedures for downgrading
the CLIM, or contact your service provider to perform the downgrade.
If the CLIM is in the STARTED state, you can determine the CLIM software version by using OSM
Low Level Link, OSM Service Connection, or by entering:
SCF > VERSION CLIM $ZZCIP.clim-name
If the CLIM is not in the STARTED state, you can use either OSM Low Level Link or the CLIMCMD
command with the Linux cat subcommand by entering:
> climcmd clim-name cat /etc/vproc
Multiple RVUs of a CLIM are allowed on a system as long as all CLIMs have CLIM RVUs that are
compatible with the host RVU.
Troubleshooting Tools and Tips 125