Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)

NOTE: The STATUS CLIM $ZZSTO.clim-name shows the status of the disk volumes
belonging to this CLIM and shows the active path (denoted by the asterisk (*) in the State
field).
d. Switch the disk paths by using the SCF SWITCH CLIM command to the Storage subsystem
($ZZSTO).
> SWITCH CLIM $ZZSTO.S1002531 , AWAY
e. Ensure the switch worked by issuing the STATUS CLIM command to the storage subsystem.
> STATUS CLIM $ZZSTO.S1002531 , DETAIL
STORAGE - Detailed Status CLIM \MYSYS.$ZZSTO.#S1002531
Configured Devices:
Name State Substate Primary PID Backup PID
$SYSTEM-P STARTED 0,257 1,257
$DATA00-P STARTED 0,327 1,310
$DATA01-P STARTED 0,326 1,313
$OSS-P STARTED 0,323 1,319
$DATA03-P STARTED 0,325 1,315
$KMSF1-P STARTED 0,324 1,317
$DATA00-MB STARTED 0,327 1,310
$DATA01-MB STARTED 0,326 1,313
$OSS-MB STARTED 0,323 1,319
$DATA03-MB STARTED 0,325 1,315
S1002531 has disk paths that have no asterisk (*) next to STARTED in the State field, which
means the paths configured on this CLIM are not active.
> STATUS CLIM $ZZSTO.S1002533 , DETAIL
STORAGE - Detailed Status CLIM \MYSYS.$ZZSTO.#S1002533
Configured Devices:
Name State Substate Primary PID Backup PID
$SYSTEM-B *STARTED 0,257 1,257
$DATA00-B *STARTED 0,327 1,310
$DATA01-B *STARTED 0,326 1,313
$OSS-B *STARTED 0,323 1,319
$DATA03-B *STARTED 0,325 1,315
$KMSF1-B *STARTED 0,324 1,317
$DATA00-M *STARTED 0,327 1,310
$DATA01-M *STARTED 0,326 1,313
$OSS-M *STARTED 0,323 1,319
$DATA03-M *STARTED 0,325 1,315
The backup disk paths are active on S1002533. Since all the disks still have active paths
provided by CLIM S1002533, you can abort CLIM S1002531.
f. Abort the Storage CLIM by issuing the SCF ABORT CLIM command to the CIP subsystem.
> ABORT CLIM $ZZCIP.S1002531
g. Ensure the CLIM is STOPPED by issuing the SCF STATUS CLIM command to the CIP subsystem.
> STATUS CLIM $ZZCIP.S1002531
CIP Status CLIM
Name Present State Trace
S1002531 Yes STOPPED OFF
h. Update the form as shown in Table 8: Sample populated Storage CLIM upgrade form
140 Upgrading CIP