Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)

Table 8 Sample populated Storage CLIM upgrade form
Normal
operations
resumed?
CLIM
restarted
?
Upgrade
done ?
Switch
and abort
done ?
B/up
CLIM
started ?B/up CLIM name
Storage
path
Running
Maint
Prov?
TypeCLIM name
If yes,
which
one?
YYS1002533PStS1002531
MB
YS1002531BStS1002533
M
i. Continue with “2. Upgrade the Storage CLIM” (page 141).
2. Upgrade the Storage CLIM
a. Perform the software upgrade as described in “Updating CLIM Software Using the OSM
Low-Level Link” (page 147)
b. Return to this procedure and continue with “3. Resume Storage CLIM Normal Operations (skip
if the host system is not running)” (page 141).
3. Resume Storage CLIM Normal Operations (skip if the host system is not running)
a. Check that the upgraded CLIM is operational.
> STATUS CLIM $ZZCIP.*
CIP Status CLIM
Name Present State Trace
N1002541 Yes STARTED OFF
N1002542 Yes STARTED OFF
N1002581 Yes STARTED OFF
N1002582 Yes STARTED OFF
N1012581 Yes STARTED OFF
N1012582 Yes STARTED OFF
O1002571 Yes STARTED OFF
O1002572 Yes STARTED OFF
S1002531 Yes STARTED OFF
S1002532 Yes STARTED OFF
b. Start the Storage CLIM if it is STOPPED.
c. Check that the disk paths configured in the Storage CLIM are started by issuing the STATUS
CLIM command to the storage subsystem.
> STATUS CLIM $ZZSTO.S1002531 , DETAIL
STORAGE - Detailed Status CLIM \MYSYS.$ZZSTO.#S1002531
Configured Devices:
Name State Substate Primary PID Backup PID
$SYSTEM-P STARTED 0,257 1,257
$DATA00-P STARTED 0,327 1,310
$DATA01-P STARTED 0,326 1,313
$OSS-P STARTED 0,323 1,319
$DATA03-P STARTED 0,325 1,315
$KMSF1-P STARTED 0,324 1,317
$DATA00-MB STOPPED 0,327 1,310
$DATA01-MB STARTED 0,326 1,313
$OSS-MB STARTED 0,323 1,319
$DATA03-MB STARTED 0,325 1,315
d. Start any stopped disk paths of the Storage CLIM by issuing the SCF RESET DISK and START
DISK commands to the storage subsystem. For example:
Upgrading CLIM Software and Firmware While Maintaining Network or Storage Traffic 141