Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)
h. Update the form.
i. Wait for about 15 minutes to make sure the system returns to normal operating condition
before updating the backup CLIM.
You have now completed the procedure for upgrading a Storage CLIM. Continue upgrade
operations until all Storage CLIMs are upgraded.
Upgrading IP CLIMs
CAUTION: During this procedure, the IP CLIM loses connectivity.
1. Prepare IP CLIMs for Upgrade (skip if the host system is not running)
This example shows the preparation step for a failover-configured CLIM. If you are performing this
step on a non-failover-configured CLIM or on a CLIM that is part of a multi-line-path Expand
configuration, start with the Abort CLIM step.
a. List the CLIMs.
> SCF
> INFO CLIM $ZZCIP.*
Name Mode Location ConnPts Provider
N1002541 IP (100 ,2 ,5 ,4 ,1 ) 1 CSAM2
N1002542 IP (100 ,2 ,5 ,4 ,2 ) 1 ZTC0
N1002581 IP (100 ,2 ,5 ,8 ,1 ) 1 ZTC0
N1002582 IP (100 ,2 ,5 ,8 ,2 ) 1 CSAM2
N1012581 IP (101 ,2 ,5 ,8 ,1 ) 1 CSAM5
N1012582 IP (101 ,2 ,5 ,8 ,2 ) 1 CSAM5
O1002571 OPEN (100 ,2 ,5 ,7 ,1 ) 1 CSAM3
O1002572 OPEN (100 ,2 ,5 ,7 ,2 ) 1 CSAM4
S1002531 STORAGE (100 ,2 ,5 ,3 ,1 ) 2 --
S1002533 STORAGE (100 ,2 ,5 ,3 ,3 ) 2 --
According to the info display there are six IP CLIMs (N1002541, N1002542, N1002581,
N1002582, N1012581, N1012582).
b. Determine which IP CLIMs are configured as failover pairs and ensure the primary and backup
interfaces are up and their link pulses are up.
> STATUS PROVIDER $ZZCIP.* , DETAILExcerpt from PROVIDER CSAM2
F Home Sts LkP Failover/(Assoc) Sts LkP Current Fovr
N1002582.bond0 UP UP N1002541.bond0 UP UP N1002582.bond0 Home
N1002582.bond1 UP UP N1002541.eth1 UP UP N1002582.bond1 Home
N1002582.eth3 UP UP N1002541.eth3 UP UP N1002582.eth3 Home
T N1002541.tun624 UP UP (N1002541.eth2) -- -- N1002541.tun624 --
N1002541.bond0 UP UP N1002582.BOND0 UP UP N1002541.bond0 Home
N1002541.eth3 UP UP N1002582.eth3 UP UP N1002541.eth3 Home
N1002541.eth2 UP UP -- -- N1002541.eth2 --
N1002541.eth1 UP UP -- -- N1002541.eth1 --
This extract shows that N1002541 and N1002582 are configured as a failover pair in
Provider CSAM2, that all failover interfaces have status UP and link pulse UP, and the interfaces
are running on their home CLIM.
NOTE: If the interfaces are not running on their home CLIMs, perform an SCF SWITCH CLIM,
RESTORE command to the CIP subsystem and check again.
c. For a failover-configured CLIM, perform a manual failover.
1. Switch the CLIM activity to the backup CLIM.
> SWITCH CLIM $ZZCIP.N1002582 , FAILOVER
Open connections still exist, okay to continue? Y
NOTE: TCP and SCTP connections are lost during a failover.
2. Ensure the switch worked.
> STATUS PROVIDER $ZZCIP.CSAM2 , DETAILExcerpt from PROVIDER CSAM2
F Home Sts LkP Failover/(Assoc) Sts LkP Current Fovr
Upgrading CLIM Software and Firmware While Maintaining Network or Storage Traffic 143