Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)
Table 11 Firmware Update Time Estimates and Calculation Form (continued)
Estimated time for your
environment (fill in the
value based on the
information in the
previous columns)CommentsEstimated time (minutes)
Number of
components
updatedT#Object
Single update2 to 41T0842SAS HBA
Firmware
This firmware is
updated serially.
2 to 4 minutes per SAS
HBAs to be updated
>1
Single update2 to 41T0842SAS HBA
BIOS
This firmware is
updated serially.
2 to 4 minutes per SAS
HBAs to be updated
>1
Single update2 to 41T0843FC HBA
Firmware
This firmware is
updated serially.
2 to 4 minutes per SAS
HBAs to be updated
>1
2 times the number of
NICs on the CLIM
Multiple NICs
on a single
CLIM
This firmware is
updated serially.
15 to 201T0841MSA70
15 to 20 minutesper
MSA70
>1
8 to 101T0841D2700
SAS disk
enclosure
8 to 10 minutes per
D2700
>1
8 to 101T0856M8390-12CG
8 to 10 minutes per
M8390-12
>1
8 to 101T0856M8391-24x
8 to 10 minutes per
M8391-24
>1
Total Time:
Performing CLIM Firmware Updates with the System Running
This procedure presents a suggested sequence for updating CLIM firmware using the OSM Service
Connection.
1. To update CLIM iLO firmware:
a. Open the OSM Service Connection Multi-Resource dialog box.
b. Click Display →Multi-Resource Actions
c. Select the resource type CLIM.
d. Choose the iLO Update action.
e. Select all the CLIMs that show the iLO Compare State attribute as Down-rev.
f. Add the selected CLIMs to the bottom pane.
Upgrading CLIM Software and Firmware While Maintaining Network or Storage Traffic 155