Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)
Collecting Network Information
To collect network configuration information for any failures detected in an IP, Telco or IB CLIM:
1. Use allow all error in SCF for the following commands:
TACL> scf info clim $zzcip.*, detail
TACL> scf status clim $zzcip.*, detail
TACL> scf info prov $zzcip.*, detail
TACL> scf status prov $zzcip.*, detail
TACL> scf status prov $zzcip.*, route, cpu 0
Run the above commands on each running CPU.
TACL> scf version $zzcip
TACL> scf version mon $zzcip.*
TACL> scf version clim $zzcip.*
TACL> scf version $ztcp0
TACL> scf version $ztcp1
2. Send the files to HP technical support.
Collecting SSH Information
To collect SSH specific information for failures such as SSOCLIM or CLIMCMD issues detected with
the CLIMs:
1. Save the output to a file.
TACL> scf info proc $zzkrn.ssh-*, detail
TACL> scf status proc $zzkrn.ssh-*, detail
2. Collect the files $system.zssh.sshcfg,$system.zssh.sshdb, and
$system.zssh.sshlog*.
3. Send the files to HP technical support.
Collecting IB Network Status
To collect the IB network status for any failures detected on an IB CLIM:
1. Collect InfiniBand network status using the following command:
CLIMCMD clim-name ibstat > /tmp/ibstat.out
2. Send the /tmp/ibstat.out file to HP technical support.
214 Collecting Data for CLIM Issues