Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)

ConnPts
Shows whether there are one or two ServerNet connections configured per fabric between
CLIM and the NonStop host system.
X1 Location
Shows the CLIM’s first X-fabric location based on the configured location.
Y1 Location
Shows the CLIM’s first Y-fabric location based on the configured location.
X2 Location
Shows the CLIM’s second X-fabric location based on the configured location. This is applicable
only when CLIM’s CONNPTS attribute is 2.
Y2 Location
Shows the CLIM’s second Y-Fabric location based on the configured location. This is applicable
only when CLIM’s CONNPTS attribute is 2.
X1 Connection Status, Y1 Connection Status, X2 Connection Status, Y2 Connection Status
Indicate whether the CLIM is connected to each ServerNet fabric at the expected location. X2
Connection Status and Y2 Connection Status are applicable only when the CLIM’s CONNPTS
attribute is 2. The possible values are:
The CLIM is correctly connected at the specified location.Connected
No operational device is connected at the specified location.Not Connected
The specified location is not configured for connection with a CLIM.Port Misconfigured
The CLIM is not configured to be connected at the specified location.Location Mismatch
The CLIM is not configured to be connected to this system.System Mismatch
The MODE attribute of this CLIM object does not match the corresponding
mode configured on the CLIM hardware.
Mode Mismatch
The number of ServerNet connections per fabric configured for this CLIM
object is different than the value configured on the CLIM hardware.
ConnPts Mismatch
Specified location is not a supported connection location for a CLIM on this
system.
Unsupported Location
Trace Status
Shows the processors that are tracing the CLIM and each trace file name. If no processor is
tracing the CLIM, the value in this field is OFF.
Last Restart Time
Shows the time of the last CLIM software restart as saved by the CLIM.
CIP/Linux Hostname
Shows the CLIM software hostname configured on the CLIM. This must be identical to CLIM
object name.
Network SW Version
Shows the version of CIP subsystem network software running on the CLIM.
Storage SW Version
Shows the version of Storage subsystem software installed on the CLIM.
Number of Socket Servers
Shows the number of Socket Server (CIPSSRV) processes running on the CLIM.
CIP/Linux Version
Shows the version of CLIM software running on the CLIM. This value is retrieved from the
/proc/version file.
CIPMAN SCF Commands 261