Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)
Interface Failover Configuration and Status
Shows the failover configuration and status for each data interfaces associated with the provider
that has been configured to support failover, showing:
Indicates special condition of interface:F
• T indicates a manually configured IPv6-over-IPv4 tunnel interface
• X indicates the interface whose failover configuration is invalid
Indicates the home interface nameHome
Indicates the failover-interface name or the name of the associate interface for a tunnel
interface. (The associate interface is shown in parentheses.)
Failover/(Assoc)
Indicates the current location (which can be different in the case of a failover). If no
failover has occurred, that is, if this is the home interface, then this value is identical
Current
to the interface name. If a failover has occurred, then this value is identical to the
failover interface (at the time of failover).
Is the failover status of the interface.Fovr
• — indicates no failover is configured
• HOME indicates the provider is running on the home interface
• BkFO indicates the provider is running on the failover interface due to a failure
• BkOP indicates the provider is running on the failover interface due to an operator
request
• BkUN indicates the provider is running on the failover interface after a CIPMAN
restart
For the home interface and the failover interface, these additional values are possible:
Interface statusSts
• -- Indicates the CLIM associated with the interface is not in the STARTED state
• UP indicates the interface resources are active and usable
• RDY indicates the interface is usable but resources are not active
• DNOP indicates the interface is down due to an operator command, and is not usable
• DOWN indicates the interface is down due to a failure on the CLIM, and is not usable
Indicates the link pulse status (UP, DOWN, or, if there is no link-pulse status, —)LkP
Example 78 shows the detailed status of the MAINTENANCE PROVIDER ZTCP0.
Example 78 STATUS Maintenance PROVIDER Detail
> STATUS PROVIDER $ZZCIP.ZTCP0, DETAIL
CIP Detailed Status PROVIDER \MYSYS.$ZZCIP.ZTCP0
State.................... STARTED
TPStatus................. Started
Type..................... MAINTENANCE
CLIM..................... N1003741
Current Access........... ( 0, 1, 2, 3 )
Trace Status:
CPU Filename
0 \MYSYS.$DATA.TEST1.TRCPRV
Interface Status & IP Address:
Name Status LkP IP Address
N1003741.eth0:0 UP UP 16.107.186.106
270 SCF Reference for CIP