Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)
Cause
A DELETE CLIM command was issued for a CLIM object that is associated with an existing
Provider object. You cannot delete a CLIM object until there are no PROVIDER objects dependent
on the specified CLIM.
Effect
The SCF command is rejected.
Recovery
To remove the CLIM object, the PROVIDER object associated with the specified CLIM must be
removed first. Use the INFO PROVIDER command to display the names of the providers and
their associated CLIMs.
CIP 00016 (zcip-err-cpu-not-avail)
CIP E00016 The CIPMON in the specified processor to be traced is in the STOPPED state.
Cause
The user issued a TRACE command but there is no CIPMON to handle that request in the specified
processor.
Effect
The SCF command is not executed.
Recovery
Issue the START MON command, then retry the TRACE command.
CIP 00017 (zcip-err-qio-resource-short)
CIP E00017 Command failed for object object-name due
to QIO error error-number.
object-name
Is the name of the object that generated the error.
error-number
Is the QIO error number encountered.
Cause
The specified SCF command required use of QIO resources, but an error in manipulating these
QIO resources caused the command to fail.
Effect
SCF ignores the command.
Recovery
Check the condition that caused the given QIO error, resolve that condition, then retry the SCF
command.
CIP 00018 (zcip-err-climconfig-db-fail)
CIP E00018 Configuration failure due to cause on
operation operation-type for object-name.
cause
Specifies what caused the error. The causes are:
• Record not found
• Record already exists
• Obsolete record version
• Record version too new
• Database is locked by another process
387