Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)

Record information is corrupted
ConfigDB operation fails
operation-type
Specifies the operation the object was performing when the error occurred. The operations
are:
Locking
Unlocking
Inserting
Deleting
Reading
Updating
object-name
Is the name of the object that generated the error.
Cause
The SCF command requires CIPMAN to manipulate the configuration database, but it failed as
specified by the cause information.
Effect
SCF ignores the command.
Recovery
Check the command and correct all problems, then try the command again. If failure persists,
contact your service provider with the cause and operation-type information.
CIP 00019 (zcip-err-open-sockets)
CIP E00019 Cannot stop object-name, open sockets still exist.
object-name
Is the name of the object that generated the error.
Cause
A STOP command cannot be executed because the object still has open sockets.
Effect
The SCF command is rejected.
Recovery
Close all sockets using the object and reissue the STOP command, or use the ABORT command
instead of the STOP command.
CIP 00020 (zcip-err-obj-busy)
CIP 00020 Object object-name is busy with other operations.
object-name
Is the name of the object that generated the error.
Cause
The object you issued the command to is busy performing other actions and cannot process the
SCF command.
Effect
SCF ignores the command.
Recovery
Wait, then try the command again. Contact your service provider if the problem persists.
388 SCF Error Messages