Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)

B Fault Codes
This appendix documents fault codes that belong to the CIP subsystem and can appear in CIP
subsystem EMS messages.
Many fault codes suggest checking software versions. To obtain this information:
Use SCF VERSION PROCESS $ZZCIP to obtain the CIPMAN version.
Use SCF VERSION MON $ZZCIP.mon to obtain the CIPMON software version.
Examine the VPROC $SYSTEM.SYSnn.ZCIPDLL file to obtain the ZCIPDLL version. (This version
should be the same as the CIPMON software version.)
Use SCF VERSION CLIM $ZZCIP.CLIM to obtain the CLIM software version or look in the
/etc/vprocfile on the CLIM.
Origin “CIP Manager Fault Code 1003
Cause
The size of the message CIPMAN received from CIPMON is inconsistent with what is expected.
Effect
The message is dropped without further processing.
Recovery
CIPMAN automatically retries the operation. If this problem persists over an extensive period of
time, make sure the appropriate versions of software (CIPMAN, CIPMON, ZCIPDLL, CLIM) are
running. If the problem persists, contact your HP service provider.
Origin “CIP Manager Fault Code 1011
Cause
A configured CLIM object is now unusable due to a problem with hardware connectivity. This
can be caused by there being no CLIM connected at the configured location, different devices
connected on different fabrics corresponding to the same configured location, or other connectivity
problems. There should also be a CIP subsystem event 5211 that provides more detailed
information.
Effect
The specified CLIM object cannot be accessed.
Recovery
Make sure that the correct CLIM hardware is connected at the correct locations and that the
CLIM and the ServerNet switch are configured correctly.
Origin “CIP Manager Fault Code 1012
Cause
There are no active CIPMON processes running in any processor on the system. This is most
likely caused by an operator request.
Effect
No access to any CLIM or provider from any processor.
Recovery
Make sure that CIPMON processes are started by the persistent manager. See “Starting CIP on
the NonStop Host System” (page 100) for information about how to start CIPMON processes.
Origin “CIP Manager Fault Code 1015
Cause
An attempt to read or write a configuration database record by the CIPMAN process fails.