Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)
Effect
For reading of a non-critical configuration database record, CIPMAN continues without access
to the object corresponding to the configuration database record. For a critical configuration
database record, CIPMAN terminates and the backup CIPMAN takes over.
Recovery
None. This is an informational event. However, if an existing CIP subsystem object (such as a
CLIM or Provider) is unexpectedly missing, you may want to restart the CIPMAN process.
Origin “CIP Manager” Fault Code 1017
Cause
A configured CLIM object is now unusable due to a mismatch between configuration on the
CLIM and configuration on the NonStop System.
Effect
The specified CLIM object cannot be brought to STARTED state.
Recovery
Make sure that the configuration on the CLIM is consistent with the configuration of the CLIM
object on the NonStop system. In particular, if the CLIM is configured with MULTIPROV set to
OFF, all network resources on the CLIM must not be associated with any specific provider or all
network resources on the CLIM must be associated with the IPDATA provider specified by the
PROVIDER attribute of the CLIM object.
Origin “CIP Manager” Fault Code 1018
Cause
A configured CLIM object is now unusable because the version of software running on that CLIM
does not support one or more features (such as MULTIPROV support) that have been turned on
for that configured CLIM object.
Effect
The specified CLIM object cannot be brought to STARTED state.
Recovery
Make sure that the CLIM is running software that can support the feature sets configured for that
CLIM object or turn off features that are not supported by the software running on the CLIM using
theSCF ALTER CLIM command.
Origin “CIP Manager” Fault Code 1019
Cause
A configured CLIM object is now unusable due to CIPMAN receiving invalid CLIM-based
configuration information from the CLIM.
Effect
The message is dropped without further processing. The specified CLIM object cannot be brought
to STARTED state.
Recovery
CIPMAN will automatically retry the operation. However, if this problem persists over an extensive
period of time, the operator should make sure that an appropriate version of the software
(CIPMAN, CIPMON, ZCIPDLL, CLIM) are running and make sure that the configuration on the
CLIM is consistent with the configuration of the CLIM object on the NonStop system. If the problem
still persists, contact your HP representative.
Origin “CIPMON” Fault Code 2001
Cause
An unexpected failure condition was encountered by a CIPMON process.
402 Fault Codes