Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)
Origin “CIPMON” Fault Code 2022
Cause
The CIPMON process receives a response message from a CLIM that has a CLIM type that was
not expected for that type of request.
Effect
The message is dropped.
Recovery
Make sure the correct and matching software is running on both the NonStop host system and
on the CLIM.
Origin “CIPMON” Fault Code 2030
Cause
A CIPMON process in either the STARTING or STARTED state is incompatible with the current
CIPMAN process. The CIPMAN protocol version is newer than that CIPMON protocol version.
Effect
The CIP subsystem does not function properly. If CIPMON is already in the STARTED state, the
current socket operations might work correctly but there are not any recovery actions. If CIPMON
is in the STARTING state, the CIP subsystem access through that processor is not available and
additional MON object transient faults (Origin “CIPMON” Fault Code 2032) are likely to be
generated.
Recovery
Install the correct, compatible versions of CIPMAN and CIPMON.
Origin “CIPMON” Fault Code 2031
Cause
A CIPMON process in either the STARTING or STARTED state is incompatible with the current
CIPMAN process. The CIPMAN protocol version is older than that CIPMON protocol version.
Effect
The CIP subsystem does not function properly. If CIPMON is already in the STARTED state, the
current socket operations might work correctly but there are not any recovery actions. If CIPMON
is in the STARTING state, the CIP subsystem access through that processor is not available and
an additional MON object transient fault (Origin “CIPMON” Fault Code 2033) is likely to be
generated.
Recovery
Install the correct, compatible version of CIPMAN and CIPMON.
Origin “CIPMON” Fault Code 2032
Cause
A CIPMON process in the STARTING state is incompatible with the current CIPMAN process.
The CIPMAN protocol version is newer than that CIPMON protocol version.
Effect
The CIP subsystem does not function properly. The CIP subsystem access through that processor
is not available
Recovery
Install the correct, compatible version of CIPMAN and CIPMON.
Origin “CIPMON” Fault Code 2033
Cause
A CIPMON process in the STARTING state is incompatible with the current CIPMAN process.
The CIPMAN protocol version is older than that CIPMON protocol version.