Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)

Recovery
This is a serious problem. Send complete information to your HP support provider for analysis.
Origin “CIPSREQ” Fault Code 3017
Cause
The CIP subsystem dynamic link library (ZCIPDLL) received an updated IP address or route (add
or delete) from the CLIM that is not consistent with what is expected.
Effect
The IP address or route is not updated within the CIP subsystem dynamic link library (ZCIPDLL)
in that processor.
Recovery
If the problem persists, a CLIM reboot is recommended.
Origin “CIPSREQ” Fault Code 3018
Cause
The size of the message the CIP subsystem dynamic link library (ZCIPDLL) attempted to send to
the CLIM is too large.
Effect
The operation fails.
Recovery
Make sure the correct and matching CIPMON, ZCIPDLL, and CLIM software versions are running.
If mismatched versions are not the cause, this is a serious problem. Send complete information
to your HP support provider for analysis.
Origin “CIPSREQ” Fault Code 3020
Cause
The CIP subsystem dynamic link library (ZCIPDLL) receives a data message from the CLIM that
is too small.
Effect
Access to the CLIM is lost.
Recovery
Make sure the correct and matching software is running on both the NonStop host system and
on the CLIM. If mismatched versions are not the cause, this is a serious problem. Send complete
information to your HP support provider for analysis.
Origin “CIPSREQ” Fault Code 3021
Cause
The CIP subsystem dynamic link library (ZCIPDLL) encounters a socket operation error that requires
CLIM access to be disconnected.
Effect
Access to CLIM is lost.
Recovery
Make sure that the correct and matching software is running on both the NonStop host system
and on the CLIM. If the problem persists, send complete information to your HP service provider
for analysis.
Origin “CIPSREQ” Fault Code 3023
Cause
The CIP subsystem dynamic link library (ZCIPDLL) detects that there is no active connection with
the CLIM.
407