Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)
Effect
The CLIM object cannot be added.
Recovery
For ErrorDetail1 = -1, check the version of MEASURE. For ErrorDetail1 = 1, retry the operation.
For all other ErrorDetail1 values, send complete information to your HP service provider for
analysis.
Origin “CIPSREQ” Fault Code 3031
Cause
The CIP subsystem dynamic link library (ZCIPDLL) receives a local IP address from the CLIM that
already exists for a different interface within the same provider.
Effect
The IP address is not associated with the interface specified in the message from the CLIM.
Recovery
Check configuration of all CLIMs associated with the same PROVIDER object to make sure the
same local IP address is not associated with more than one interface for all associated CLIMs.
Origin “CIPSREQ” Fault Code 3032
Cause
The CIP subsystem dynamic link library (ZCIPDLL) cannot support any more objects of the specified
object type.
Effect
The specified object cannot be added.
Recovery
None. This is an informational message. If a new object is needed, an existing object must be
removed first.
Origin “CIPSREQ” Fault Code 3033
Cause
The CIP subsystem dynamic link library (ZCIPDLL) encounters a check-sum error for a data message
from the specified CLIM.
Effect
Access to the CLIM is lost.
Recovery
This is most likely a hardware problem. If the problem persists for the same CLIM, have the CLIM
hardware replaced. If the problem persists for multiple CLIMs, there may be a hardware problem
associated with a NonStop host system processor. Contact your HP service provider for support.
Origin “CLIMAGT” Fault Code 5120
Cause
CLIM configuration information (most likely the CLIM name) within the current START CLIM request
from the NonStop host system does not match the CLIM configuration information of the first
successful START CLIM request received by the CLIMAGT. This indicates that different NonStop
host system processors are sending START CLIM requests to the CLIMAGT with conflicting CLIM
configuration information.
Effect
The current START CLIM request is rejected. The CLIM is not accessible from that NonStop host
system processor.
410 Fault Codes