Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)

Recovery
This is a serious problem. Send complete information (both NonStop host system and CLIM) to
your HP support provider for analysis.
Origin “CLIMAGT” Fault Code 5121
Cause
The processor number associated with the START CLIM request from the NonStop host system
is not valid (for example, not between 0 and 15).
Effect
The current START CLIM request is rejected. CLIM is not accessible from that NonStop host system
processor.
Recovery
This is a serious problem. Send complete information (both NonStop host system and CLIM) to
your HP support provider for analysis.
Origin “CLIMAGT” Fault Code 5122
Cause
The CLIM name provided within the START CLIM request from the NonStop host system does
not match the CLIM host name information.
Effect
The current START CLIM request is rejected. The CLIM is not accessible from that NonStop host
system processor.
Recovery
Make sure that CLIM hostname information matches the CLIM name on the NonStop host system
.
Origin “CLIMAGT” Fault Code 5124
Cause
CLIMAGT calls to the transport library results in an error. This is most likely caused by an inability
to obtain necessary resources.
Effect
The current CLIM request failed.
Recovery
Make sure there is sufficient memory on the CLIM. If the problem persists, reboot the CLIM.
Origin “CLIMAGT” Fault Code 5125
Cause
The CLIMAGT encounters an error when it attempts to fetch detailed information about a CLIM
for which this CLIM has backup information. This is likely caused by a stale directory entry under
/etc/clim/mirror with no files in the subdirectory associated with that CLIM name.
Effect
The CLIM configuration cannot be obtained. The CLIM cannot be brought to the STARTED state.
Recovery
If the problem persists, reboot all CLIMs associated with the IPDATA provider belonging to the
problem CLIM. If that does not work, contact your HP service provider.
Origin “CLIMAGT” Fault Code 5126
Cause
The CLIMAGT cannot allocate memory.
411