Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)
Effect
The current CLIM request failed.
Recovery
Make sure there is sufficient memory on the CLIM. If the problem persists, reboot the CLIM.
Origin “CLIMAGT” Fault Code 5127
Cause
The CLIMAGT did not receive configuration information from CLIMMON.
Effect
The current CLIM request failed.
Recovery
Check if the CLIMMON process is running. Restart the CLIMMON process if necessary. If the
problem persists, send complete information to your HP service provider for analysis.
Origin “CLIMAGT” Fault Code 5128
Cause
The NonStop host system processor that sends the current request is not in the STARTED state
with respect to that CLIM, so the current request cannot be processed.
Effect
The current CLIM request failed.
Recovery
None. The CIP subsystem should automatically recover. If the problem persists, send complete
information, especially from the NonStop host side, to your HP service provider for analysis.
Origin “CLIMAGT” Fault Code 5131
Cause
The interface specified in the current request does not seem to be a configured interface.
Effect
The current CLIM request failed.
Recovery
Check to make sure interface is configured using climconfig command.
Origin “CLIMAGT” Fault Code 5132
Cause
The interface specified in the current request has been stopped by the operator.
Effect
Current CLIM request failed. Interface cannot be brought to active state.
Recovery
Bring the specified interface to an operational state by using the ifstart command.
Origin “CLIMAGT” Fault Code 5133
Cause
The tunnel interface specified in current request has its parent interface in a non-active state.
Effect
The current CLIM request failed. This tunnel interface cannot be brought to the active state.
412 Fault Codes