Cluster I/O Protocols (CIP) Configuration and Management Manual (H06.16+, J06.05+)
> DELETE CLIM N1002532
CIP E00015 CLIM $ZZCIP.N1002532 is associated with an existing
Maintenance Provider object.
4. Find the associated Maintenance Provider:
> INFO CLIM N1002532, detail
CIP Detailed info CLIM \MYSYS.$ZZCIP.N1002532
Mode........................... IP
Configured Location............ Group 100 , Module 2 , Slot 5 , Port 3 , Fiber 2
ConnPts........................ 1
X1 Location.................... Group 100 , Module 2 , Slot 5 , Port 3 , Fiber 2
Y1 Location.................... Group 100 , Module 3 , Slot 7 , Port 3 , Fiber 2
SvNet ID 1..................... 192.168.37.82
Network CLIM Information:
MultiProv....................... OFF
Provider........................ ZTC00
Index........................... 0
Maintenance Providers Configured:
ZTCP1........................... 192.168.37.99
NOTE: The Fiber field is displayed only for systems that support it.
5. Abort the maintenance Provider:
> ABORT PROVIDER ZTCP1, forced
6. Delete the maintenance Provider.
a. Record the current configuration:
> INFO PROVIDER ZTCP1, obey
ADD PROVIDER $ZZCIP.ZTCP1 , &
TPNAME $ZTCP1 , &
HOSTNAME "osmlany" , &
HOSTID 0.0.0.0 , &
TCP-LISTEN-QUE-MIN 128 , &
TYPE MAINTENANCE , &
CLIM N1002532
IPADDRESS 192.168.36.11
b. Delete the Provider:
> DELETE PROVIDER ztcP1
7. Delete the CLIM:
> DELETE CLIM N1002532
8. Add the CLIM using the required data Provider:
> ADD CLIM N1002532, mode ip, connpt 1, location (100,2,5,3,2), provider ztc01
9. Add a maintenance Provider using recorded attributes:
> ADD PROVIDER ztcp1, type maint, clim n1002532,
ip 192.168.36.11, hostname "osmlany"
10. Start the CLIM:
> START CLIM n1002532
11. Start the maintenance Provider:
> START PROVIDER ztcp1
12. Check the configuration:
> INFO CLIM *
CIP Info CLIM
Name Mode Location ConnPts Provider MultiProv
Configure CLIM-To-CLIM Failover (Applies to IP CIP Only, Not Storage CIP) 67