Expand Configuration and Management Manual (H06.21+, J06.10+)
Subsystem Control Facility (SCF) Commands
Expand Configuration and Management Manual — 529522-013
14 - 15
ALTER LINE Command
For more information on the line attributes that have corresponding profile modifiers,
see the description of the corresponding profile modifier in Section 16, Expand
Modifiers.
These Line attributes do not have corresponding profile modifiers:
CLBDWNLOADRETRIES integer
specifies the maximum number of times that the Expand line-handler process will
try to download a communications line interface processor (CLIP). This attribute
applies to ServerNet wide area network (SWAN) concentrators. The valid range for
this attribute is 2 to 255. The default is 3.
CLBDWNLOADTIMR time
specifies the time interval that the Expand line-handler process will wait for the
successful completion of a communications line interface processor (CLIP)
download operation. This attribute applies to ServerNet wide area network (SWAN)
concentrators only. The time interval is specified in the format described in
Time
Values on page 14-6.
The valid range for this attribute is 30.00 seconds to 5:27.67 minutes. The default
is 30.00 seconds.
CLBIDLETIMER time
specifies the time interval that the Exp
and line-handler process will wait before
sending successive status probes to the communications line interface processor
(CLIP). A value of 0 indicates that no status probe will be issued. This attribute
applies to ServerNet wide area network (SWAN) concentrators only. The time
interval is specified in the format described in Time Values on page 14-6.
RXWINDOW RXWINDOW n
SPEED SPEED n
SPEEDK SPEEDK n
SRCIPADDR SRCIPADDR n
SRCIPPORT SRCIPPORT n
TIMERINACTIVITY TIMERINACTIVITY n
TIMERPROBE TIMERPROBE n
TIMERRECONNECT TIMERRECONNECT n
TXWINDOW TXWINDOW n
V6DESTIPADDR V6DESTIPADDR n
V6SRCIPADDR V6SRCIPADDR n
Table 14-4. ALTER LINE Attributes and Corresponding Profile
Modifiers
(page 2 of 2)
SCF Attribute Profile Modifier