Expand Configuration and Management Manual (H06.21+, J06.10+)
Subsystem Control Facility (SCF) Commands
Expand Configuration and Management Manual — 529522-013
14 - 42
Expand-Over-ATM Line-Handler Processes
Associatedev
reports the name of the ATM line associated with the Expand-over-ATM line-
handler process.
Associatesubdev
reports the name of the ATM service access point (SAP). The only currently
supported ATM SAP is #IP.
Example 14-10 shows the display format for a LINE object with the DETAIL option for
Expand-over-ATM line-handler processes that use permanent virtual circuits (PVCs).
The asterisk (*) indicates an alterable attribute.
L2Protocol
is the Layer 2 protocol process associated with the Expand-over-IP line-handler
process.
TimeFactor
reports the current configured or calculated time factor for this lin
e. For a
discussion about time factors, including how to calculate them, see Routing and
Time Factors on page 17-22.
SpeedK
calculates the time factor of the line for the Expand routing algorithm. A value of
NOT_SET means that this parameter was not set. For a discussion of SPEEDK,
see
SPEEDK n on page 16-23.
Framesize
specifies the maximum size frame that can be sent in the network; smaller frames
can be sent. The Expand subsystem also uses the FRAMESIZE modifier to
calculate the packet size and determine the size of the frame buffers. If the default
FRAMESIZE modifier value is used, the packet size is 132 words.
Example 14-10. INFO LINE, DETAIL Command, Expand-Over-ATM Line-Handler
Processes
-> INFO LINE $AMLBA0, DETAIL
EXPAND Detailed Info LINE $AMLBA0 (LDEV 307)
L2Protocol Net^Atm TimeFactor...... 1 *SpeedK........ OC12
Framesize....... 132 -Rsize........... -Speed........
*LinePriority.... 1 StartUp......... OFF Delay......... 0:00:00.10
*DownIfBadQuality OFF *QualityThreshold 96 *QualityTimer.. 0:01:00.00
*Txwindow........ 7 *Maxreconnects... 0 *AfterMaxRetries PASSIVE
*Timerreconnect 0:00:30.00 *Retryprobe...... 19 *Timerprobe.... 0:00:01.00
*Associatedev.... $AM2 *Associatesubdev #IP *Timerinactivity 0:00:00.00
ConnEp....... %H2061CF10 ListenEp.... %H00000000 *CallType...... PVC
*PvcName......... PVC10
*LineTf.......... 0