OBEYFORM Option
PvcName
is the name of the permanent virtual circuit (PVC).
LineTF
is the line time factor. LINETF has a range of 0 to 186, with a default of 0 (unset). If
you set LINETF, it overrides the RSIZE, SPEED, or SPEEDK parameters in
calculating the time factor for the line (PATHTF overrides all parameters, including
LINETF). If LINETF is left unset (a zero value), this parameter is not used in setting
the time factor.
OBEYFORM Option
The output is in the form of an ALTER LINE command, containing the alterable
modifiers for the corresponding line type. This allows for easy creation of SCF
command files for configuration backup.
Example 14-11. INFO LINE $<line-name>, OBEYFORM command for Expand over
ATM line
-> INFO LINE $ATM,OBEYFORM
ALTER LINE $ATM ,&
LINEPRIORITY 1 ,&
SPEEDK OC12 ,&
QUALITYTIMER 0:01:00.00 ,&
QUALITYTHRESHOLD 96 ,&
DOWNIFBADQUALITY OFF ,&
MAXRECONNECTS 0 ,&
AFTERMAXRETRIES PASSIVE ,&
TIMERRECONNECT 0:00:30.00 ,&
RETRYPROBE 19 ,&
TIMERPROBE 0:00:01.00 ,&
TIMERINACTIVITY 8:20:50.00 ,&
LINETF 0 ,&
ASSOCIATEDEV $ATM ,&
ASSOCIATESUBDEV #IP ,&
CALLTYPE PVC ,&
PVCNAME PVC00 ,&
TXWINDOW 7