Expand Configuration and Management Manual (H06.21+, J06.10+)
Expand Modifiers
Expand Configuration and Management Manual — 529522-013
16 - 21
PVCNAME n
when the line is started. For more information on the DLC tasks, see the WAN
Subsystem Configuration and Management Manual.
PVCNAME n
Default: None
Units: Not applicable
Range: Not applicable
This modifier is applicable to Expand-over-ATM line-handler processes that used
permanent virtual circuit (PVC) connections. This modifier identifies the name of the
PVC used by the Expand-over-ATM line-handler process. Only the name portion of the
PVC name should be specified (for example, PVC01).
QUALITYTHRESHOLD n
Default: 98
Units: Integers
Range: 0 through 99
If the line reports quality lower than this percentage value, a timer is started. See also
DOWNIFBADQUALITY ON/ DOWNIFBADQUALITY OFF and QUALITYTIMER n.
This modifier is applicable to both single-line and multi-line IP, ATM, satellite, and
SWAN line-handler processes.
QUALITYTIMER n
Default: 0
Units: hh:mm:ss
Range: 0 through 12 hours
This modifier specifies the time interval to wait af
ter the line quality drops below the
threshold value specified in the QUALITYTHRESHOLD before taking the action
specified in the parameter DOWNIFBADQUALITY. See also
QUALITYTHRESHOLD n
and DOWNIFBADQUALITY ON/ DOWNIFBADQUALITY OFF.
This modifier is applicable to both single-line and multi-line IP
, ATM, satellite, and
SWAN line-handler processes.
RETRYPROBE n
Default: 19 for IP and ATM lines
10 for Expand-over-ServerNet lines
20 for Expand-over-NAM lines
Units: seconds
Range: 1 through 255
This modifier specifies the number of times the Exp
and-over-NAM or Expand-over-
ServerNet line-handler process will retry its probe of the network access method