Expand Configuration and Management Manual (H06.21+, J06.10+)
Troubleshooting
Expand Configuration and Management Manual — 529522-013
20 - 24
Expand-Over-ATM Problems
Detailed State Field for Expand-Over-ATM Lines
Table 20-14 describes the detailed states displayed in the Detailed State field for
Expand-over-ATM line-handler processes.
Table 20-14. Detailed States (Expand-Over-ATM) (page 1 of 2)
Detailed State Cause/Effect Recovery
ACCEPT A switched virtual circuit (SVC)
connection
has been accepted
from the remote system.
This state is normal. No
recovery is required.
BINDING The Expand-over-ATM line-handler
pro
cess is binding to the configured
permanent virtual circuit (PVC)
name.
This state is normal while the line is
coming up.
If the line remains in
this state, an internal error might
have occurred.
This state is normal. No
recovery is requ
ired.
CALLING The Expand-over-ATM line-handler
pro
cess is attempting to establish a
switched virtual circuit (SVC)
connection to the remote system.
This state is normal. No
recovery is required.
CONNECTED A connection has been established This state is normal. No
recovery is requ
ired.
CONNECTING The Expand-over-ATM line-handler
pro
cess is attempting to connect to
the remote (destination) Expand-
over-ATM line-handler process.
This state is normal while the
connection
is being established. If
the line remains in this state, the
remote Expand-over-ATM line-
handler process can not be
operational or there can be a
network problem.
Use the SCF STATS LINE
and
SCF INFO LINE
commands to further
diagnose the problem. These
commands are described in
Resolving Expand-Over-ATM
Connection Problems on
page 20-26.
DOWN The Layer 2 functions of the
Exp
and-over-ATM line-handler
process are down. The operator
might have brought the line down,
the line was never started, or a
problem occurred that prevented
the line from starting.
If an error has occurred,
additional information will
appear in the Detailed Info
field. The Detailed Info field is
described in
Detailed Info
Field for Expand-Over-ATM
Lines on page 20-27.
DOWN WAIT This is an internal state that should
not
persist.
Try to restart the line. If this
state persists, contact your
HP representative.