Expand Configuration and Management Manual (H06.21+, J06.10+)
Configuration Quick Start
Expand Configuration and Management Manual — 529522-013
1 - 17
Where to Find More Information About This Task
2. To create lines in the multi-line path (called line-logical devices), use the SCF ADD
DEVICE command syntax shown for configuring single-line Expand line-handler
processes (see Creating a Single-Line Expand Line-Handler Process on page 1-6),
but with these exceptions:
•
Use the TYPE modifier values as shown in Table 1-8.
•
Omit the NEXTSYS modifier; it was specified when you configured the path-
logical device.
•
Include the MULTI modifier as:
MULTI $path_name
where path_name is the name of the path-logical device you created in
Step 1.
These rules apply when creating line-logical devices:
•
You can configure a maximum of eight lines in a multi-line path.
•
The path-logical device and all the line-logical devices with which it is associated
must be configured in the same processor pair.
An example of an SCF ADD DEVICE command that adds a line-logical device for an
Expand-over SNA line:
-> ADD DEVICE $ZZWAN.#LINE2, PROFILE MLHSNA,&
IOPOBJECT $SYSTEM.SYS01.LHOBJ, CPU 0, ALTCPU 1,&
TYPE (63,2), RSIZE 0, PATHTF 3, ASSOCIATEDEV $SNA1,&
ASSOCIATESUBDEV #SNAM, MULTI $PATH
Where to Find More Information About This Task
Section 7, Configuring Direct-Connect and Satellite-Connect Lines
Section
8, Configuring Expand-Over-IP Lines
Section
9, Configuring Expand-Over-ATM Lines
Section 10, Configuring Expand-Over-X.25 Lines
Section
11, Configuring Expand-Over-SNA Lines
Table 1-8. Subtypes for Line-Logical Devices
Type of Line-Logical
Device TYPE Modifier Value Profile
Direct-connect (63,6) PEXQMSWN
Satellite-connect (63,6) PEXQMSAT
Expand-over-X.25 (63,2) PEXQMNAM
Expand-over-SNA (63,2) PEXQMNAM
Expand-over-IP (63,2) PEXQMIP
Expand-over-ATM (63,2) PEXQMATM