Task 5: Start the Expand Line-Handler Process
Section 12, Configuring Expand-Over-ServerNet Lines
Section 13, Configuring Multi-Line Paths
Task 5: Start the Expand Line-Handler Process
Start the single-line Expand line-handler process or path-logical device. When you use
this command to start a path-logical device, the line-logical devices associated with the
path are also started.
-> START DEVICE $ZZWAN.#device_name
where device_name is the device name of the Expand line-handler process or p
ath-
logical device.
Establishing a Connection
To establish a connection between two Integrity NonStop NS-series servers, repeat the
tasks described in this section to create an Expand line-handler process at the
neighbor system.
If the neighbor system is a NonStop K-series server (or other type of NonStop system),
you must use the system generation program or the COUP interface to the Dynamic
System Configuration (DSC) utility to create an Expand line-handler process at the
neighbor system.
For more information, see the System Generation Manual for Expand or the Dynamic
System Configuration (DSC) Manual in the D-series documentation.
After you have configured and started Expand line-handler processes at both the local
and destination systems, you can start the Expand line (or lines).
Starting an Expand Path
To start a single-line path, use this command:
-> START LINE $device_name
where device_name is the name of a single-line Expand line-handler process.
Starting Lines in a Multi-Line Path
To start all the lines in a multi-line path, use this command:
-> START PATH $path_name
where path_name is the name of a the p
ath-logical device.
To start specific lines in a multi-line p
ath, use this command:
-> START LINE $line_name
where line_name is the name of a logical device.