NonStop NS2200 Series Planning Guide
Blade Element Group-Module-Slot Numbering (NS2200T and NS2200ST Systems)
• Group:
In OSM Service Connection displays, 400 through 403 relates to blade complexes 0
through 4. Each blade complex includes a blade element and its associated processor.
Example: group 403 = blade complex 3
◦
◦ In the OSM Low-Level Link, 400 relates to all blade complexes.
Example: group 400 = any blade complex
• Module:
In OSM Service Connection displays, a module represents either the blade element or
the processor:
◦
– In a NonStop NS2200 series system, all blade elements are module 1.
Example: module 1 = any blade element
– 100-103 relates to processors 0-3
Example: module 102 = processor 2
◦ In the OSM Low-Level Link, 100 through 103 relates to processors 0 through 3.
Example: module 103 = processor 3
• Slot:
In OSM Service Connection displays:◦
– 1 represents the ServerNet PCI adapter card.
The ServerNet PCI card is installed in PCI slot 1 in the rx2800 i2.
– 3 and 4 represent the power supplies on the blade element.
OSM slot 3 represents power supply 1; OSM slot 4 represents power supply 2.
– 32 through 37 represent the fans on the blade element.
OSM slot 32 represents fan 1, OSM slot 33 represents fan 2, and so on.
◦ In the OSM Low-Level Link, 1 relates to the location of the processor. Because each blade
element contains only one processor, it is always located in slot 1.
Example: slot 1 = any processor in any blade element.
• Port: X and Y relate to the two ServerNet fabric ports in slot 1.
Example: Port X = Right port connecting to the ServerNet X fabric when facing the blade
element from the rear.
These tables show the default numbering for the blade elements of a NonStop NS2200 system
when blade elements are powered on and functioning:
120 NonStop NS2200T and NS2200ST Systems Overview