NonStop NS2200 Series Planning Guide

CG Maintenance Switch Specifications
ValueSpecification
Enclosure Dimensions
1 UU Height
1.7 in (4.32 cm)Height
17 in (43.2 cm)Width
9 in (22.9 cm)Depth
Enclosure Weight
5 lbs (2.3 kg)Unboxed
Power and Heat
2Number of power inputs
35 WTypical power consumption
40 WMaximum power consumption
119 BTU/hourTypical heat dissipation
136 BTU/hourMaximum heat dissipation
CG Maintenance Switch Ground Connections
The CG maintenance switch has a threaded post located to the right of the DC input terminal block.
A ground cable connects from this grounding post to the nearest cabinet grounding rail. For detailed
information about connecting the ground cables, ask your HP service provider to refer to the
NonStop NS2200 Series Installation Manual.
Data Cables
The enclosures in this system are suitable for connection to intrabuilding or non-exposed wiring or
cabling only. Unshielded, twisted-pair (UTP) cables may be used for both NEBS™ and non-NEBS
installations.
Seismic Cabinet and Enclosure Weights Worksheet
The total weight of each cabinet is the sum the weight of the cabinet plus each enclosure installed
in it. All weights are approximate. Use this worksheet in Table 7 (page 138) to calculate the weight.
Because this worksheet list both types of seismic racks, you should cross out the one that does not
apply and not include it in your calculations.
Table 11 Seismic Rack Weight Worksheet
Weight Worksheet for Seismic Rack Number _____
TotalWeight
Number of
EnclosuresEnclosure Type kglbkglb
7.316Fuse panel
23.652Blade Element
2862VIO Enclosure
2862DL380 G6 CLIM CG
28.663DL380p Gen8 CLIM CG
Data Cables 147