NonStop NS2200 Series Planning Guide

1
This cable cannot be used in certain configurations. For affected configurations and maximum cable lengths, see “Cable
Length Restrictions” (page 173).
Cable Length Restrictions
Maximum allowable lengths of cables connecting the modular system components are:
Product IDMaximum LengthConnectorsFiber
Type
Connection
M8900nnn
1
125 mLC-LCMMFBlade element to
VIO enclosure
(ServerNet-to-
processor port)
M8920nnn
1
50 mMTP-MTPMMFVIO enclosure to
VIO enclosure
(cross-link
connection)
M8906nnn
1
6 mSFF-8088 to
SFF-8088
MMFDL380 G6
Storage CLIM to
SAS disk
enclosure, copper
M8906-066 (max length)SFF-8088 to
SFF-8088
MMFDL380p Gen8
Storage CLIM to
M8381-25,
copper
2
SAS disk
enclosure
M8906-066 (max length)SFF-8088 to
SFF-8088
MMFDL380p Gen8
Storage CLIM to
M8391-24CG
and
M8392-24CG,
copper SAS disk
enclosure
M8900nnn
1
Maximum LengthTransfer RateLC-LCMMF
OM2
Storage CLIM (FC
HBA interface) to
ESS
3
300 m
4
2 Gbps
150 m4 Gbps
50 m8 Gbps
Customer suppliedMaximum LengthTransfer RateLC-LCMMF
OM3
500 m2 Gbps
380 m4 Gbps
150 m8 Gbps
M8900nnn
1
Maximum LengthTransfer RateLC-LCMMF
OM2
Storage CLIM (FC
HBA interface) to
FC tape
300 m
4
2 Gbps
150 m4 Gbps
50 m8 Gbps
Customer suppliedMaximum LengthTransfer RateLC-LCMMF
OM3
500 m2 Gbps
380 m4 Gbps
150 m8 Gbps
Cable Length Restrictions 173